RADIATION PROTECTION

Mobile Radiation Shields & Lead Barriers

Mobile lead barriers, portable shields and radiation screens for operating theatres, cath labs, X-ray and intervention rooms in Singapore and Malaysia.

Mobile shielding for theatre, cath lab and X-ray rooms

Mobile radiation shields add a fixed layer of protection between staff and the source, so teams rely less on worn PPE alone. They can be repositioned between procedures and moved between rooms on casters.

The ACOVIC range includes the Maxx Safe height-adjustable wrap-around shield, the Porta Shield for patient protection during diagnostic procedures, a multi-panel radiation shield screen that sits beside the table, and mobile lead barriers from 0.6 to 2 mmPb and above, with or without lead-glass viewing windows.

  • Height-adjustable mobile wrap-around shield
  • Portable patient shield on casters
  • Multi-panel table-side shield screen
  • Mobile lead barriers with or without lead-glass windows
  • 0.5 to 2+ mmPb options

Mobile Shields & Barriers

Maxx Safe Mobile Shield – ACOVIC mobile radiation shield
Product Code #15004

Maxx Safe Mobile Shield

Mobile wrap-around radiation shield. Height adjustable 1050–1350mm, 360° casters. 0.5/1.0/1.5mmPb. For OR, cath lab and intervention rooms.

Porta Shield – ACOVIC mobile radiation shield
Product Code #15002

Porta Shield

135x70cm portable shield on casters with adjustable height — ideal for patient protection during diagnostic procedures. 0.5/1.0/1.5mmPb.

Radiation Shield Screen – ACOVIC mobile radiation shield
Product Code #15005

Radiation Shield Screen

Portable multi-panel shield that positions beside the table without disrupting workflow, reducing scatter radiation during fluoroscopy.

Mobile Barrier A – ACOVIC mobile radiation shield
Product Code #16001

Mobile Barrier A

90 x 180cm mobile lead barrier, no window. 0.6/1.0/1.5/2++mmPb. Reduces scatter exposure during x-ray and fluoroscopy.

Mobile Barrier B – ACOVIC mobile radiation shield
Product Code #16002

Mobile Barrier B

90 x 190cm mobile barrier with a 20 x 20cm lead-glass window. 0.6/1.0/1.5/2++mmPb.

Mobile Barrier C – ACOVIC mobile radiation shield
Product Code #16003

Mobile Barrier C

90 x 190cm mobile barrier with a 60 x 80cm lead-glass window. 0.6/1.0/1.5/2++mmPb.

Mobile Barrier E – ACOVIC mobile radiation shield
Product Code #16005

Mobile Barrier E

107 x 194cm mobile barrier with a 60 x 100cm lead-glass window. 0.6/1.0/1.5/2++mmPb.

Mobile Barrier F – ACOVIC mobile radiation shield
Product Code #16006

Mobile Barrier F

Two-tier mobile barrier panel, no window. 0.6/1.0/1.5/2++mmPb.

Frequently asked questions

Do mobile shields replace lead aprons?

No. Mobile shields and barriers complement aprons, thyroid shields and glasses by adding a fixed barrier between staff and the scatter source. Use them together for the best protection.

Should I choose a barrier with or without a window?

A lead-glass window lets staff see the patient and equipment while staying behind the barrier. Mobile Barriers B, C and E have windows from 20 x 20 cm to 60 x 100 cm, while Barriers A and F have no window.

What lead equivalence do mobile barriers come in?

The mobile barriers are available from 0.6 mmPb up to 2 mmPb and above, and the mobile shields from 0.5 to 1.5 mmPb. The right level depends on the X-ray energies and workload in the room, so a shielding assessment by your medical physicist is recommended.

Can the shields be moved between rooms?

Yes. The mobile shields and barriers are on casters, and the Maxx Safe shield has 360° casters and height adjustment from 1050 to 1350 mm.

Do you supply mobile radiation shields in Singapore and Malaysia?

Yes. ForthMed supplies ACOVIC mobile shields and lead barriers in Singapore and Malaysia. Contact us for quotations and product information.

Need a quotation or product advice?

Our teams in Singapore and Kuala Lumpur can help you choose the right radiation protection for your department.

Contact UsAll Radiation Protection